Garner MDS4J Garner MDS-4J Media Degausser, 100 VAC, 60 Hz
|
|
|
|
|
|
|
|
|
|
|
|
|
Limited Stock Call 800-660-3586 |
|
|
|
|
|
|
|
|
|
|
|
The Garner MDS-4 is designed to handle VHS and S-VHS and all formats of magnetic media up to 16 inches in diameter. It operates continuously in the low field strength setting, and intermittently in the high field setting.
On the low power setting, which is continuous, the unit will provide complete erasure on VHS, Beta, and audio cassettes, as well as computer reel tape. In the high setting, this unit will erase media with up to 950 oersted, including formats such as 1 inch reels, U-matic, S-VHS, DAT, 3480 and 8mm.
Not designed for LTO or DLT tapes.
Features- Inexpensive VHS and S-VHS degausser
- Fully automatic and easy to operate
- Erases all formats of media up to 950 oersted including audio, video and data tapes, and diskettes
- High and low field strength switch allows continuous duty erasing on the low setting and intermittent duty erasing on high
- Automatic cooling fan increases duty cycle
- Conservative design insures long, reliable performance
- Strong horizontal and vertical degaussing fields ensure complete erasure
- Built-in timer has adjustable 'on' cycle
- Automatic thermal protection
Applications- Police Departments
- Security Systems Managers
- TV Broadcasters
- Military organizations
- MIS departments
- Banks and financial institutions
- Corporate security departments
- Corporate audio/video departments
- Broadcast stations
- Government MIS departments
Media Erased- VHS and S-VHS
cassette's
- Betacam, U-Matic, and U-Matic SP cassette's
- 1
inch computer, audio, and video reels
- 10 1/2 inch computer reels
- Audio cassettes
- Diskettes
- 4mm and 8mm cassette's
- 3480, 3490, and 3490e tape cartridges
- Video Pancakes
|
|
|
|
| Power |
8A @ 110 VAC, 50 or 60 Hz.
4A @ 220 VAC, 50 or 60 Hz. |
| Controls |
On/Off Automatic Timer Switch
High / Low field Strength Setting
|
| Gauss Field Strength |
High: 2500 Gauss Low: 2000 Gauss |
| Indicators |
Lighted On/Off Main Power Lamp
Lighted Overheat Lamp Temperature Lamp |
| Cooling |
Automatic Fan System and
Vented Enclosure |
| Run Time |
10 Minutes (Cold Start) High Field Setting.
Continuous Low Field Setting. |
| Dimensions (H x W x D) |
4" x 13" x 17" |
| Weight |
48 lbs |
| Warranty |
One Year |
|
|
|